+971 4 331 0000
QX16/2 and QX16/4 LSZH are high performance and exceptional quality installation speaker cables with the added bonus of a fully certificated LSZH fire rated design. They deliver excellent levels of performance in all multi-room and home cinema installations.
Large cross-sectional area of high purity copper conductors
Ensures good performance levels are maintained even on longer runs
Sequentially metre marked - counting down so you always know what you have left on the reel or in the box
Colour-coded conductor sheaths
Fully tested LSZH Design
Full test report available on request
RoHS2 Compliant
Supplied in 100m (328ft) PRObox & on 300m (984ft) reel
Conductor Size | 16 AWG | |
Conductor Construction | 30/0.25 | |
Conductor Resistance | 13.3 Ω/km | |
Conductor Cross-sectional Area | 1.5 mm2 | |
Insulation Colour | 16/2 | Red, Black |
16/4 | Red, Black, White, Green |
Dielectric Strength | 600 kV AC | |
Jacket Material | LSZH | |
Outside Diameter | 16/2 | 6.20 mm |
16/4 | 7.20 mm | |
Jacket Colour | Pink | |
Weight | 16/2 | 58 kg/km |
16/4 | 98 kg/km |
Conductor Size
16 AWG
Conductor Construction
30/0.25
Conductor Resistance
13.3 Ω/km
Conductor Cross-sectional Area
1.5 mm2
Insulation Colour
16/2
Red, Black
16/4
Red, Black, White, Green
Dielectric Strength
600 kV AC
Jacket Material
LSZH
Outside Diameter
16/2
6.20 mm
16/4
7.20 mm
Jacket Colour
Pink
Weight
16/2
58 kg/km
16/4
98 kg/km
Most cables feature PVC insulation, some have a basic fire rating such as CL3, etc. Unfortunately, most cables give off hazardous toxic smoke during a fire, posing a very serious health risk.
LSZH cables are made from a special compound that performs as well as PVC insulation, but crucially gives off very little smoke and no halogen toxins in the event of a fire.
Many leading architects and builders along with commercial and marine designers are now specifying LSZH spec cables as standard.
Only LSZH cables meet the legislated fire specifications for boat installations.
Each complete QED Professional cable design is fully tested to LSZH standards and reports are available on request.
We don't just use a fire rated jacket material over an ordinary cable assembly; each complete cable design including jacket and all internal conductors has to undergo rigorous fire safety testing to the following standards:IEC 61034-1:2005
IEC 61034-2:2005
Measurement of smoke density of cables burning under defined conditions.
IEC 60332-1:2004
Test for vertical flame propagation for a single insulated wire or cable.
IEC 60754-2:1991
(Amendment1, 1997) test on gas evolved during combustion of electric cables.
CONNECT YOUR:Hi-fi Home theatre systems
TO YOUR:Speakers